Inlet flange 100 ISO-K 160 ISO-K
Rotation speed 39,000 rpm
Pumping speed
    N2 320 l/s 410 l/s
    He 290 l/s 360 l/s
    H2 180 l/s 230 l/s
Compression rate
    N2 1 x 108
    He 2 x 103
    H2 1 x 102
Ultimate pressure w/out purge
measured according to Pneurop standard
8 x 10-9 mbar
Maximum pressure at inlet in continuous operation     1 mbar
Maximum permissible pressure at exhaust 5 mbar
Noise level ≤ 39 dBA
Start-up time < 3 min
Maximum start-up power 650 W
Maximum operating power 300 W
N2 purge flow rate 50 SCCM
Cooling water flow rate < 60 l/h
Water temperature 15 < T < 25°C
Maximum ambient temperature 40°C
Weight 19 kg / 42 lbs
Recommended forepump ADP 31