Home > Power Supplies > DC Sputtering > Advanced Energy > Pinnacle > Advanced Energy AE Pinnacle PLUS+ 10kW 400V Power Supply 3152436-348
Email Link Tweet This Share on Facebook

Advanced Energy AE Pinnacle PLUS+ 10kW 400V Power Supply 3152436-348

90 Day Warranty 

Request for Quote

To request a quote, click the button below and fill out the form.

RFQ

Manufacturer Part Number: 3152436-348
Advanced Energy AE Pinnacle PLUS+ 10kW 400V Power Supply 3152436-348
Click Image to Enlarge

Advanced Energy AE Pinnacle PLUS+ 10kW 400V Power Supply 3152436-348

Microprocessor Advantages

The internal microprocessor checks for proper circuit operation while supervising all operating parameters. System diagnostics run when the unit is initially powered up. The most recent power settings and conditions (such as output production) are retained in non-volatile memory.

Displays

The displays on the passive panels as well as the control panels show power, current, or voltage levels. (The displays show levels for unit A and unit B if this is a dual unit). They also display information about output, setpoint, interlock, bus fault, over temperature, arcs, and error codes.

Arc-Suppression Feature

With the Pinnacle's arc-handling feature enabled, the hard-arc detection time is less than 1µs, and delivered are energy is less than 10 mJ for a kW inverter. (Depending on your unit's output configuration, the energy could be significantly less than 10 mJ).

Additionally, the arc-suppression feature enables you to implement preprogrammed arc-handling functions during your normal process cycle and your target conditioning cycle (TCC). In this mode the arc detect time and arc shutdown time are fixed by target type (metal or nonmetal). But you may also customize your arc shutdown and arc detect delay times by selecting the custom mode. Other parameters, including long arc count limit and voltage trip level, arc selectable through the Pinnacle Remote Active Panel or serial communications (Host) port.

Pinnacle PLUS+ Specifications

Specifications 5 kW, Single Output 5 kW, Dual Output 10 kW, Single Output
Max output power 5 kW 5 kW, independently controlled outputs 10 kW
Voltage Range 325 to 650 VDC; optional 325 to 800 VDC output (wide Z)
Max Current 15.4 ADC 15.4 ADC per output 30.8 ADC
Input Power Connector Five-terminal, DIN compression terminal block; maximum wire size: #6 AWG
Output Connector Two-terminal, multi-contact, pluggable connector with strain relief or UHF connector
Frequency 5 to 350 kHz, variable
Reverse Time 0.4 to 5 ±s, variable; Optional 0.4 to 10 ±s range
Duty Cycle Up to 45% reverse time, variable
Reverse Voltage 10% of operating voltage (just prior to reversal)
Ignition Capability 1,500 VDC max, 1,350 VDC typical
Regulation Modes Power, voltage, or current
Repeatability From run to run at constant set point: 0.1% from 10 to 100% of rated power
AC Line Voltage 200/208 or 400 or 480 VAC
Current 200/208 VAC: 17 A nominal per φ
400 VAC: 8.5 A nominal per φ
480 VAC: 7.5 A nominal per φ
200/208 VAC: 35 A nominal per φ
400 VAC: 17 A nominal per φ
480 VAC: 15 A nominal per φ
Regulatory Compliance CE, NRTL on certain models
Ground Reference Negative, positive, or floating output up to 1500 VDC with respect to ground or terminal to terminal
Analog Interface Options 37-pin isolated (to 500 VRMS), 0 to 10 VDC analog, 0/24 VDC digital
37-pin, 0 to 10 VDC or 0 to 5 VDC isolated analog, 0/15 VDC digital
37-pin, 0 to 10 VDC or 0 to 5 VDC non-isolated analog, 0/15 VDC digital
Serial Communication Options RS-232, RS-422, RS-485 (selectable baud rates up to 57.6 k): AE Bus protocol; ASCII protocol (MDX and emulation)
Profibus (selectable baud rates of 1.5 MB or 12 MB); AE Bus protocol
DeviceNet± option available
Accessory Remote, active monitor/control panel
Weight 21.4 kg (47 lb) 30 kg (66 lb)
Max Recommended Output Cable Length 10 m (32.8') RG393 or equivalent
Cooling Medium Air
Input Power Connector Five-terminal, DIN compression terminal block; maximum wire size: #6 AWG
Output Connector Two-terminal, multi-contact, pluggable connector with strain relief or UHF connector

Request for Quote

Need modifications to this item? PTB Sales' expert team of engineers can configure products to your specific needs. Please follow the above link, and fill out the quote form.

Advanced Energy AE Pinnacle PLUS+ 10kW 400V Power Supply 3152436-348

3152436-101 		PNCL PLUS+ 10K 400 AFP EE P16
3152436-102 		PNCL PLUS+ 10K 400 PFP EE P16
3152436-103 		PNCL PLUS+ 10K 400 PFP KI P11
3152436-106 		PNCL PLUS+ 10K 400 AFP KY P16
3152436-107 		PNCL PLUS+ 10K 400V PFP KH P16 ADCAP 
3152436-108 		PNCL PLUS+ 10K 400 AFP EP P16
3152436-302 		PNCL PLUS+ 10K 400 AFP NI P11 SYNCH 
3152436-303 		PNCL PLUS+ 10K 400 PFP NI P11 SYNCH
3152436-304 		PNCL PLUS+ 10K 400 AFP HH P11 SYNCH 
3152436-309 		PNCL PLUS+ 10K 400 BFP NY M32 SYNCH 
3152436-310 		PNCL PLUS+ 10K 400 PFP EH P11 SYNCH 
3152436-349 		PNCL PLUS+ 10K 400 AFP HE P11 SYNCH 
3152436-350 		PNCL PLUS+ 10K 400 PFP NY P11 SYNCH 
3152436-351 		PNCL PLUS+ 10K 400 AFP NH P16 SYNCH 
3152436-352 		PNCL PLUS+ 10K 400 PFP EE P16 SYNCH 
3152436-353 		PNCL PLUS+ 10K 400 AFP EE P16 SYNCH 
3152436-354 		PNCL PLUS+ 10K 400 PFP HE P16 SYNCH 
3152436-355 		PNCL PLUS+ 10K 400 PFP HH P16 SYNCH 
3152436-356 		PNCL PLUS+ 10K 400 PFP NI P11 SYNCH 800V 
3152436-357 		PNCL PLUS+ 10K 400 AFP HE P16 SYNCH 800V 
3152436-358 		PNCL PLUS+ 10K 400 PFP KI P11 SYNCH 800V 
3152436-359 		PNCL PLUS+ 10K 400 AFP HP P16 M/S 800V 
3152436-360		PNCL PLUS+ 10K 400 PFP NY P16 SYNCH 800V

Product Reviews

There are currently no customer reviews for this product.

Be the first to write a review!
We value your opinion. Please take a moment and share what you like or don't like about a product.

Write a review now