Home > Vacuum Pumps > Diffusion > Agilent Varian > HS - REBUILT > Agilent Varian NHS-35 Diffusion High Vacuum Pump - REBUILT

Agilent Varian NHS-35 Diffusion High Vacuum Pump - REBUILT

Manufacturer Part Number: F1730308
Price: $18,550.00
Quantity:
Agilent Varian NHS-35 Diffusion High Vacuum Pump - REBUILT
Click Image to Enlarge

Agilent Varian NHS-35 Diffusion High Vacuum Pump - REBUILT

These diffusion pumps come with full thermal protection and quick-cool coils. HS-16 through 35 come with sight glass / fill and drain assemblies. Our HS-32 pumps have 32" ASA flanges. The Agilent Varian HS-20 pump is wired for either 208V or 240V. For $1,500 we will convert them to 480V. We also carry Agilent Varian diffusion pump LN2 traps and baffles and valves. 

Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!

Agilent Varian NHS-35

Model Number: Type HS-16
0164
HS-20
0165
HS-32
0167
NHS-35
0169
Speed (l/s)
Air 10,000 17,500 32,000 50,000
Hydrogen 12,500 22,000 40,000 62,500
Helium
Normal operating range 1 x 10E-3 to
< 5 x 10E-8
8 x 10E-4 to < 5 x 10E-8
Untrapped, Torr 1.3 x 10E-3 to
6.5 x 10E-9
1 x 10-3 to
< 6.5 x 10-8
1 x 10E-3 to
< 6.5 x 10E-8
6.5 x 10E-4 to
< 6.5 x 10E-8
Max. fore pressure, Torr
No load 0.65 0.50 0.55
Full load 0.55 0.35 0.40
Max. throughput, @ 1 x 10-2 Torr 12.5 @ 8,100 W 18 35
13.5 @ 9,600 W
Min. recommended backing pump for max. throughput
cfm 80 100 300
Backstreaming rate @ inlet flange
(mg/cm2/min) 1.5 x 10-3 7 x 10-4 5 x 10-4
Warmup time (min) 30 45 30 60
Cooldown time (min) w/ quick cool coil where applicable 60
Fluid charge 3 Qts. (2.8 l) 5 Qts. (4.7 l) 3 Gal. (11.4 l)
Electrical requirements 3-phase
50/60 Hz
240/480 V
Power (watts) 8,100/9,600 12,000 24,000 24,000
Cooling water U.S. gpm @ 60 - 80°F (15 - 26 ) 1.5 1.5 4.0 4.0
Weight (lbs) 500 600 1,500 1,500

Request for Quote

Need modifications to this item? PTB Sales' expert team of engineers can configure products to your specific needs. Please follow the above link, and fill out the quote form.

Agilent Varian NHS-35 Diffusion High Vacuum Pump - REBUILT

F1730308 / F1730-308  ASA w/ standard cold cap 240V
F1730318 / F1730-318  ASA w/ halo baffle 240V
F1730326 / F1730-326  ASA w/ standard cold cap 415V
F1730336 / F1730-336  ASA w/ halo baffle 415V
F1730309 / F1730-309  ASA w/ standard cold cap 480V
F1730319 / F1730-319  ASA w/ halo baffle 480V
L5924308 / L5924-308  ISO w/ standard cold cap 240V
L5924318 / L5924-318  ISO w/ halo baffle 240V
L5924326 / L5924-326  ISO w/ standard cold cap 415V
L5924336 / L5924-336  ISO w/ halo baffle 415V
L5924309 / L5924-309  ISO w/ standard cold cap 480V
L5924319 / L5924-319  ISO w/ halo baffle 480V