Home > Vacuum Pumps > Dry > Edwards > GV DRYSTAR - REBUILT > Edwards GV600 / EH4200 Vacuum Blower System - REBUILT

Edwards GV600 / EH4200 Vacuum Blower System - REBUILT

Green Tag - Best Offerings

Request for Quote

To request a quote, click the button below and fill out the form.

RFQ

Edwards GV600 / EH4200 Vacuum Blower System - REBUILT
Click Image to Enlarge

Edwards GV600 / EH4200 Vacuum Blower System - REBUILT

Rebuilt with one year warranty. Edwards EH4200 vacuum blower and GV600 dry pump package. We also offer repair service. View our inventory of Edwards blowers and DRYSTAR pumps.

Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!

Specifications GV600
Construction 3 claw + 1 roots
Displacement 793 m3h-1 / 467 ft3min-1
Pumping speed* 560 m3h-1** / 330 ft3min-1**
Ultimate pressure < 0.05 mbar / < 0.0375 Torr
Power consumption at 10 mbar / 7.5 Torr     7 Kw / 9.4 hp
Motor Rating 22.5 kW / 30 hp
Cooling-water flow at 20°C 5.5 l min-1 / 1.43 gal min-1
Seal purge (dry air) < 22 l min-1 @ 0.4 bar / < 0.6 ft-3 @ 6 psig
Noise level 80 dB(A)
Inlet connection ISO100
Outlet connection ISO63
Weight 950 kg / 2,100 lbs
Gear box oil capacity 1.6 liter / 0.42 gal
Electrical supply 380/415V 50 Hz 3 ph

 

* Measured in accordance with Pneurop 6602 at 40°C

** GV600 @ 1 mbar 

Specifications EH4200
Displacement (swept volume)
    50 Hz 4,140 m3h-1 / 2,440 ft3min-1
    60 Hz 4,985 m3h-1 / 2,935 ft3min-1
Effective pumping speed with backing pump
    E2M275 3,100 m3h-1 / 1,825 ft3min-1
Pressure differential across pump
  50 Hz
    HC 70 mbar / 52 Torr
    FX 60 mbar / 46 Torr
  60 Hz
    HC / FX 60 mbar / 38 Torr
Inlet connection ISO250
Outlet connection ISO100
Rotating speed
    50 Hz 2,900 rpm
    60 Hz 3,500 rpm
Operating continuous inlet pressure 1,000 mbar / 760 Torr
Maximum outlet pressure 1,000 mbar / 760 Torr
Recommended backing pumps GXS450, E2M275, ES300, ES630, 412J, IDX1000, IDX1300
Motor power
    Hydrocarbon 11 kW / 15 hp
    PFPE 11 kW / 15 hp
    ATEX 11 kW / 15 hp
Ambient temp. range
    Operating 5 to 40°C / 40 to 104°F
    Storage -20 to 80°C / 14 to 176°F
Max. operating humidity 90% RH
Recommended cooling water supply pressure     2-6 barg
Cooling water connections 3/8 inch BSP male
Recommended cooling water flow 6 lmin-1
Recommended oil
    Standard version Ultragrade 20
    PFPE version Fomblin YVAC 16/6
Oil capacity
    Coupling cover 6.5 l
    Shaft seal reservoir 0.45 l
    Gear case 3.5 litre
Weight 485 kg / 1067 lb

Request for Quote