Manufacturer Part Number: DC22M-A041300111AL
MKS ENI DCG 200A DC Magnetron Stand-Alone 20kW Power Supply
Click Image to Enlarge

MKS ENI DCG 200A DC Magnetron Stand-Alone 20kW Power Supply

The MKS ENI DC magnetron power supply has the same connection and cable configuration as the MDX magnetron. It can be swapped with an MDX with no other changes than the voltage taps. The DCG takes slaves as well to increase power output, which requires upgrading the master software. The MKS Optima OPT-20 is the latest in this line.

Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!

Output regulation modes Volts, amperes, watts
Output control modes Ramping, time, run, joule, sequence, constant run
Output power range "Zero" to "Output Power Rating"
Output power rating 10/15/20/25/30/35/40/45/50/60 kW or Dual 10/15/20/30 kW (fixed value, configured by using a 20 kW or Dual 10 kW master unit either alone or in combination with one or two 20 kW slave units and/or with one or two DCG-100 series 5 kW and/or 10 kW slave units)
Output power limit [fixed value set at factory (selected from optional values shown here, for the given unit type); predetermined by customer-changeable continuous DC output voltage rating and continuous DC output current limit] "Low-Z, High-Current" Unit Type
    100/105/105% of "Output Power Rating"
"High-Current" Unit Type
    105/105/105% of "Output Power Rating"
"Low-Z" Unit Type
    100/105/105% of "Output Power Rating"
"Standard" Unit Type
    105/105/105% of "Output Power Rating"
"High-Voltage" Unit Type
    105/105/105% of "Output Power Rating"
Continuous DC output voltage range "Zero" to "Continuous DC Output Voltage Rating"
Continuous DC output voltage rating [fixed value set at factory (selected from optional values shown here, for the given unit type); transformer tap setting that determines Continuous DC Output Voltage Rating is customer­changeable by following applicable procedure in product manual; nominal line conditions assumed] "Low-Z, High-Current" Unit Type
    200/250/322V
"High-Current" Unit Type
    250/312/400V
"Low-Z" Unit Type
    400/500/645V
"Standard" Unit Type
    500/625/800V
"High-Voltage" Unit Type
    1,000/1,250/1,600V
Ambient air temperature 5-40°C
Ambient air relative humidity 80% RH (max) at up to 31°C; decreasing linearly to 50% RH (max) at 40°C
Installation category Installation Category (Overvoltage Category) II: Local level, appliances, portable equipment, etc., with smaller transient overvoltages than distribu­tion level and fixed equipment.
Shock resistance Exceeds the requirements of IEC 65-2-6 test Fc for vibration, IEC 68-2-29 test Eb for bump, and IEC 68-2-31 test Ec for topple.
Cooling method Forced-air (equipped with two rear panel-mounted DC cooling fans)
Cooling-air total flow rate 140 cfm
Cooling-air inlets Front panel
    Two side-by-side 32 x 141 mm rectangular openings (backed by EMI screen); lower-justified on panel
Port-side panel
    One centrally-positioned, 26 x 102 mm array of 39 round holes; lower-justified on panel; port-side panel is panel on left, while facing unit's rear panel
Cooling-air outlets Rear panel
    Two side-by-side 117 x 117 mm rounded octagonal openings (covered by finger guards); upper-justified on panel
Nominal voltage & current (20 kW) DCG-200A
    200-208V ± 10%, 3/PE~, 75 A per phase (at Output Power Rating)
DCG-200E
    400V ± 10%, 3/PE~, 45 A per phase (at Output Power Rating)
DCG-200Z
    N. America: 380-480V ± 5%, 3/PE~, Europe: 400V ± 10%, 3/PE~; 45 A per phase (at Output Power Rating)
Nominal frequency 50/60 Hz ± 2%
Power factor 0.75 (at output Power Rating)
Optional front panel types Dual-Master & Master units
  • Fully-Functional
  • Blank (with three L.E.D. indicators)
  • Remote (fully-functional; used to interact with Dual-Master & Master units equipped w/ blank front panel)
Slave units
  • Blank (w/ three L.E.D. indicators)
AC input connector options (to maintain product NRTL Listing, permanent rack-installation is required for units equipped with a ring lug-terminated AC input line cord) Hard-Wired units
    Dead-Front Terminal Block
Cord-Connected units
    Ring Lugs
DC output connector options / Dual-Master & Master units  
    Connector "A": 5/8-in OD Panel-Mount Bushing, Tapped 3/8-in Deep with 1/4-28 UNF-2B Thread (ENI Part No. 000-1039-756); "Continuous DC Output Current Rating" maximum < 25A
    Connectors "A", "B (1 pin/terminal min.)", "C", "D", "D" & "E" together "F"
    Connector "B": MIL-C-26482 Series II Circular Connector (ENI Part No. 221609); 25 A < "Continuous DC Output Current Rating" maximum < 50 A
    Connectors "A", "B (2 pins/terminal min.)", "C", "D", "D" & "E" together "F"
    Connector "C": Cooper Industries, USD Products Magnum® Series B4000 Bulkhead Terminal Block (ENI Part No. 651027); 50 A < "Continuous DC Output Current Rating" maximum < 75A
    Connectors "A", "B (3 pins/terminal min.)", "C"
    Connector "D": UHF Coaxial Panel Receptacle, Military No. SO-239A (ENI Part No. 221742); 75A < "Continuous DC Output Current Rating" maximum < 100 A
    Connectors "A", "B (4 pins/terminal)"
    Connector "E": UHF Coaxial Angle Adapter (ENI Part No. 221741); 100 A < "Continuous DC Output Current Rating" maximum < 200 A
    Connector "A" only
DC output connector options / Slave units  
    Connector "F": UHF Coaxial Front-Mount Bulkhead Receptacle, Military No. SO-239 (ENI Part No. 221457); "Continuous DC Output Current Rating" maximum < 25A
    Connector "G (1 pin/terminal min.)"
25 A < "Continuous DC Output Current Rating" maximum < 50 A
    Connector "G (2 pins/terminal min.)"
    Connector "G": Positronic Industries POWR-LOK® Connector (ENI Part No. 221461) 50 A < "Continuous DC Output Current Rating" maximum < 75A
    Connector "G (3 pins/terminal min.)"
75 A < "Continuous DC Output Current Rating" maximum < 100 A
    Connector "G (4 pins/terminal)"
Optional DC input connector [for connection with Slave DC output(s)] Positronic Industries, Inc. PLB Series, 8-Pin, Dual-Row (2 x 4 ), 90° PCB-Mount POWR-LOK® receptacle (Positronic Industries Part No. PLB08F4BN0A1)
Control I/O connectors RS 232/422 w/ ENI Protocol
    9-Pin "D" Sub-Miniature receptacle
Analog interface (optional)
    15-Pin "D" Sub-Miniature receptacle
Emulation interface (optional)
    37-Pin "D" Sub-Miniature receptacle
Interlock connector Weidmuller Inc. Type SL902 2-Pin, 90° PCB Header w/ open ends (Weidmuller Part No. 1126.6)
Remote front panel connector Amp Incorporated 6-Pin modular connector (AMP Part No. 520470-3)
Slave interface connector 15-Pin "D" Sub-Miniature receptacle
Electromagnetic compatibility (EMC) EMC Compliant w/ standards:
    EN 50081-2: 1992 Group 2, Class A
    EN 50082-2: 1995
Product safety NRTL Listed to standards:
    CAN/CSAC22.2 No.1010.1-92 / Category 290
    EN61010-1: 1993 / Category 387
    EN61010-1: 1993 / A2: 1995
    UL3111-1: 1994 / Category 435
CE compliance CE marked
Equipment internal fuse ratings DCG-200A
    Fuses F1 - F3 on assembly 1000-315 / 3AT, 250V
DCG-200E & DCG-200Z
    Fuses F1 - F3 on assembly 1000-415 / 3AT, 500V

Request for Quote