The MKS ENI DC magnetron power supply has the same connection and cable configuration as the MDX magnetron. It can be swapped with an MDX with no other changes than the voltage taps. The DCG takes slaves as well to increase power output, which requires upgrading the master software. The MKS Optima OPT-20 is the latest in this line.
Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!
Output regulation modes | Volts, amperes, watts |
Output control modes | Ramping, time, run, joule, sequence, constant run |
Output power range | "Zero" to "Output Power Rating" |
Output power rating | 10/15/20/25/30/35/40/45/50/60 kW or Dual 10/15/20/30 kW (fixed value, configured by using a 20 kW or Dual 10 kW master unit either alone or in combination with one or two 20 kW slave units and/or with one or two DCG-100 series 5 kW and/or 10 kW slave units) |
Output power limit [fixed value set at factory (selected from optional values shown here, for the given unit type); predetermined by customer-changeable continuous DC output voltage rating and continuous DC output current limit] | "Low-Z, High-Current" Unit Type 100/105/105% of "Output Power Rating" "High-Current" Unit Type 105/105/105% of "Output Power Rating" "Low-Z" Unit Type 100/105/105% of "Output Power Rating" "Standard" Unit Type 105/105/105% of "Output Power Rating" "High-Voltage" Unit Type 105/105/105% of "Output Power Rating" |
Continuous DC output voltage range | "Zero" to "Continuous DC Output Voltage Rating" |
Continuous DC output voltage rating [fixed value set at factory (selected from optional values shown here, for the given unit type); transformer tap setting that determines Continuous DC Output Voltage Rating is customerchangeable by following applicable procedure in product manual; nominal line conditions assumed] | "Low-Z, High-Current" Unit Type 200/250/322V "High-Current" Unit Type 250/312/400V "Low-Z" Unit Type 400/500/645V "Standard" Unit Type 500/625/800V "High-Voltage" Unit Type 1,000/1,250/1,600V |
Ambient air temperature | 5-40°C |
Ambient air relative humidity | 80% RH (max) at up to 31°C; decreasing linearly to 50% RH (max) at 40°C |
Installation category | Installation Category (Overvoltage Category) II: Local level, appliances, portable equipment, etc., with smaller transient overvoltages than distribution level and fixed equipment. |
Shock resistance | Exceeds the requirements of IEC 65-2-6 test Fc for vibration, IEC 68-2-29 test Eb for bump, and IEC 68-2-31 test Ec for topple. |
Cooling method | Forced-air (equipped with two rear panel-mounted DC cooling fans) |
Cooling-air total flow rate | 140 cfm |
Cooling-air inlets | Front panel Two side-by-side 32 x 141 mm rectangular openings (backed by EMI screen); lower-justified on panel Port-side panel One centrally-positioned, 26 x 102 mm array of 39 round holes; lower-justified on panel; port-side panel is panel on left, while facing unit's rear panel |
Cooling-air outlets | Rear panel Two side-by-side 117 x 117 mm rounded octagonal openings (covered by finger guards); upper-justified on panel |
Nominal voltage & current (20 kW) | DCG-200A 200-208V ± 10%, 3/PE~, 75 A per phase (at Output Power Rating) DCG-200E 400V ± 10%, 3/PE~, 45 A per phase (at Output Power Rating) DCG-200Z N. America: 380-480V ± 5%, 3/PE~, Europe: 400V ± 10%, 3/PE~; 45 A per phase (at Output Power Rating) |
Nominal frequency | 50/60 Hz ± 2% |
Power factor | 0.75 (at output Power Rating) |
Optional front panel types | Dual-Master & Master units
|
AC input connector options (to maintain product NRTL Listing, permanent rack-installation is required for units equipped with a ring lug-terminated AC input line cord) | Hard-Wired units Dead-Front Terminal Block Cord-Connected units Ring Lugs |
DC output connector options / Dual-Master & Master units | |
Connector "A": 5/8-in OD Panel-Mount Bushing, Tapped 3/8-in Deep with 1/4-28 UNF-2B Thread (ENI Part No. 000-1039-756); | "Continuous DC Output Current Rating" maximum < 25A Connectors "A", "B (1 pin/terminal min.)", "C", "D", "D" & "E" together "F" |
Connector "B": MIL-C-26482 Series II Circular Connector (ENI Part No. 221609); | 25 A < "Continuous DC Output Current Rating" maximum < 50 A Connectors "A", "B (2 pins/terminal min.)", "C", "D", "D" & "E" together "F" |
Connector "C": Cooper Industries, USD Products Magnum® Series B4000 Bulkhead Terminal Block (ENI Part No. 651027); | 50 A < "Continuous DC Output Current Rating" maximum < 75A Connectors "A", "B (3 pins/terminal min.)", "C" |
Connector "D": UHF Coaxial Panel Receptacle, Military No. SO-239A (ENI Part No. 221742); | 75A < "Continuous DC Output Current Rating" maximum < 100 A Connectors "A", "B (4 pins/terminal)" |
Connector "E": UHF Coaxial Angle Adapter (ENI Part No. 221741); | 100 A < "Continuous DC Output Current Rating" maximum < 200 A Connector "A" only |
DC output connector options / Slave units | |
Connector "F": UHF Coaxial Front-Mount Bulkhead Receptacle, Military No. SO-239 (ENI Part No. 221457); | "Continuous DC Output Current Rating" maximum < 25A Connector "G (1 pin/terminal min.)" 25 A < "Continuous DC Output Current Rating" maximum < 50 A Connector "G (2 pins/terminal min.)" |
Connector "G": Positronic Industries POWR-LOK® Connector (ENI Part No. 221461) | 50 A < "Continuous DC Output Current Rating" maximum < 75A Connector "G (3 pins/terminal min.)" 75 A < "Continuous DC Output Current Rating" maximum < 100 A Connector "G (4 pins/terminal)" |
Optional DC input connector [for connection with Slave DC output(s)] | Positronic Industries, Inc. PLB Series, 8-Pin, Dual-Row (2 x 4 ), 90° PCB-Mount POWR-LOK® receptacle (Positronic Industries Part No. PLB08F4BN0A1) |
Control I/O connectors | RS 232/422 w/ ENI Protocol 9-Pin "D" Sub-Miniature receptacle Analog interface (optional) 15-Pin "D" Sub-Miniature receptacle Emulation interface (optional) 37-Pin "D" Sub-Miniature receptacle |
Interlock connector | Weidmuller Inc. Type SL902 2-Pin, 90° PCB Header w/ open ends (Weidmuller Part No. 1126.6) |
Remote front panel connector | Amp Incorporated 6-Pin modular connector (AMP Part No. 520470-3) |
Slave interface connector | 15-Pin "D" Sub-Miniature receptacle |
Electromagnetic compatibility (EMC) | EMC Compliant w/ standards: EN 50081-2: 1992 Group 2, Class A EN 50082-2: 1995 |
Product safety | NRTL Listed to standards: CAN/CSAC22.2 No.1010.1-92 / Category 290 EN61010-1: 1993 / Category 387 EN61010-1: 1993 / A2: 1995 UL3111-1: 1994 / Category 435 |
CE compliance | CE marked |
Equipment internal fuse ratings | DCG-200A Fuses F1 - F3 on assembly 1000-315 / 3AT, 250V DCG-200E & DCG-200Z Fuses F1 - F3 on assembly 1000-415 / 3AT, 500V |