MKS ENI MWD-55LD
Manufacturer Part Number: MWD-55LD-01
USED MKS ENI MWD-55LD RF 13.56 MHz Matching Network
Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!
Rated RF power | 300 kVA max |
RF input power | 50 - 5,500 W |
Frequency | 13.56 MHz |
Input impedance | 50Ω |
Output impedance (standard) | 1-8Ω, real part |
Output impedance (extended) | Consult factory |
Temperature | Operational: 5 to 45°C, 0-95% RH Storage: 25 to 70°C; 0-95% RH |
RF input connector | UG-352 AIU (small LC-type) |
RF output connector | ENI P/N 012-9007-800 coaxial assy |
HVDC input connector | UG-931/U (HV BNC) |
Digital interface SYSTEM port | RS-232: 300-115,200 baud, 8 data, 1 stop, no parity |
Digital interface DEBUG port | RS-232: 19,200 baud, 8 data, 1 stop, no parity |
AC input power required | 100 to 240 VAC, ±10%, 47~63 Hz, 1-phase, < 180 VA |
AC input receptacle | DOK #CE05-2A 18-1 0PD-B |
Mating AC cable connector plug (required for SEMI 592-3 approval) |
DOK #CE05-6A18-10SD |
AC power switch | Illuminated rocker switch |
Operation | Standalone automatic; automatic, remote or manual w/ external control |
Pre-positioning | Automatic, remote or manual control of both tuning elements |
Control / monitoring | Serial digital control and monitoring. Parallel analog interface for monitoring only. |
Size (H X D X W) | 500 mm x 480.1 mm x 176.3 mm (19. 7" X 18.9" X 6.94") |
Weight | 22.7 kg (50 lbs) |
Maximum operating altitude | 2,000 m (6,562 ft) above sea level |
Cooling system | Forced-air cooling; water-cooling is optional |
Cooling water | Not used in MWD-55LD-01 |
Inlet temperature rating | 5-35°C (41-95°F) |
Pressure range | 30-45 psi |
Flow rate minimum | 1.0 ltr/min (0.27 gal/min) |
Temperature rating | 5-40°C (41-104°F) |
Relative humidity rating | 80% RH (max.) at up to 31°C (88°F), de-rated linearly to 50% RH (max.) at 40°C (104°F) |
Installation (overvoltage) category | INSTALLATION CATEGORY II: Local level, appliances, portable equipment, etc., with smaller transient overvoltages than distribution level and fixed equipment. |
Pollution degree | POLLUTION DEGREE 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. |
Electromagnetic compatibility (EMC) | EMC compliant with standards: EN 50081-2 : 1992 Group 2, Class A EN 50082-2 : 1995 |
Product safety | NRTL listed to standards: CAN/CSA C22.2 No. 1010.1-92 Category 290 EN 61010-1 : 1993/A2: 1995 (Pending) Category 387 UL3111-1 : 1994 Category 435 |
CE compliance | CE marked |
Equipment internal fuse ratings | Fuse F1 (ENI P/N 311002) on controller PCB assy. (ENI PIN 000-9004-300) 10 AF, 125 V fuse F1 (ENI P/N 301034) on component power supply (ENI PIN 501002) 4 AF, 250 V, 5 x 20 mm |