Home >
Vacuum Pumps
>
Turbo
>
Agilent Varian
>
TwisTorr & Turbo-V - REBUILT
> Agilent Varian Turbo-V 1001 Navigator - REBUILT
Agilent Varian Turbo-V 1001 Navigator - REBUILT
Agilent Varian Turbo-V 1001 Navigator Turbomolecular Vacuum Pump - REBUILT
Each turbo pump must match its controller in reference to the same class. For example, the TV 550 pump must match a V550 (stand alone, brick or PCB) controller. We also offer repair service.
Questions? Please call our toll free number at 866-332-0500 or send an email to our sales team!
Pumping speed (l/s) | N2: 250 l/s, He: 220 l/s, H2: 200 l/s |
Compression ratio | N2: 2 x 108, He: 1 x 105, H2: 1 x 104 |
Base pressure* | w/ recommended mechanical fore- pump: 2 x 10-10 mbar (1.5 x 10-10 Torr) with recommended diaphragm fore pump: 2 x 10-8 mbar (1.5 x 10-8 Torr) |
Inlet flange | DN 100 CFF (6" O.D.) DN 100 ISO |
Foreline flange | NW 16 KF |
Rotational speed | 56,000 rpm |
Start-up time | < 3 minutes |
Recommended forepump | Two stage rotary pump SD-40 Diaphragm pump: MDP 30 |
Operating position | Any |
Cooling requirements | Natural air convection Forced air or water optional |
Operating ambient temperature | + 5°C to + 35°C |
Coolant water | flow: 30 l/h (0.13 GPM) temperature: + 10°C to + 30°C pressure: 3 to 4 bar |
Bakeout temperature | 120°C at inlet CF flange maximum 80°C w/ ISO flange |
Vibration level (displacement) | < 0.01 μm at inlet flange |
Noise level | 45 dB(A) at 1 meter |
Input | 58 VAC, three phase, 933 Hz |
Lubricant | permanent lubrication |
Storage temperature | - 20°C to + 70°C |
Weight kg (lbs) | ISO: 7.5 (3.4); CFF: 11.4 (5.2) |
Need modifications to this item? PTB Sales' expert team of engineers can configure products to your specific needs. Please follow the above link, and fill out the quote form.
Agilent Varian Turbo-V 1001 Navigator Turbomolecular Vacuum Pump - REBUILT 9698933 / 969-8933 ISO-160 9698931 / 969-8931 ISO-200 9698946 / 969-8946 ISO-200F bolted 9698932 / 969-8932 ISO-250 9698934 / 969-8934 ISO-250F bolted