Rebuilt Brooks/CTI On-Board Cryo Pumps
 | | Pump | Inlet Flange |
|---|
| 4 | - | | 4F | - | | 6 | - | | 8 | 10" CF, 6" ASA, ISO 200 | | IS-8 | 10" CF, 6" ASA, ISO 200 | | 8F | 10" CF, 6" ASA, ISO 200 | | IS-8F | 10" CF, 6" ASA, ISO 200 | | P300 | 10" CF, 6" ASA, ISO 200 | | 10 | 10" ASA | | 10F | 10" ASA | | 250F | ISO 250 | | IS-250F | ISO 250 | | 400 | 16" ASA, CVC, ISO 400 |
|
Call for a quote, which includes a one year warranty. Ask us for options you would like included e.g. a three phase motor or a Fast Regen module.
Technical Data
| On-Board | 4F | 8 | 8F | 250F | 10 | 10F | 400 |
|---|
| Pumping speed - liters/second |
| Water Vapor | 1,100 | 4,000 | 4,000 | 6,500 | 9,000 | 9,500 | 17,500 |
| Air | 370 | 1,500 | 1,500 | 2,200 | 3,000 | - | 6,000 |
| Hydrogen | 370 | 2,500 | 2,200 | 3,200 | 5,000 | - | 12,000 |
| Argon | 310 | 1,200 | 1,200 | 1,800 | 2,500 | - | 5,000 |
| Cryo capacity - standard liter |
| Argon | 210 | 1,000 | 1,000 | 1,000 | 2,000 | - | 2,500 |
| H2(5x10-6 Torr) | 3 | 17 | 12 | 16 | 24 | 24 | 42 |
| Nominal Regeneration Time (cold to cold) - hours |
| Both Stages | 1.3 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 3.0 |
| Second Stage | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.5 |
| Weight (lbs) | 70 | 88 | 85 | 110 | 125 | 120 | 175 |
Brooks CTI On-Board cryogenic vacuum pumps incorporate embedded microprocessor control to enhance performance, perform diagnostic routines and provide communication capability. The On-Board Network module is included in the price.
Features
- Regenerates in half the time of a typical Cryo-Torr cryo pump.
- Simultaneous regeneration capability, enabled by networking your cryo pumps, to speed the overall system regeneration.