Rebuilt Edwards EDP & GV Industrial DRYSTAR Pumps

gv400
PumpRebuilt
EDP120ask
DP250/EDP200ask
EDP300ask
GV-250ask
GV-400ask
GV-600ask

We also offer repair service.


Technical DataGV-400GV-250
Displacement348 cfm240 cfm
Pumping speed252 cfm186 cfm
Ultimate pressure<0.4 mbar / <0.3 Torr
Power consumption @ 10 mbar8.2 kW / 11 hp7.4 kW / 9.9 hp
Motor rating22.5 kW / 30.2 hp15 kW / 20.1 hp
Cooling-water flow @ 20 °C<41 min-1 / <1.1 US gal/min
Seal purge (dry air)<22 min-1, 0.4 bar
0.6 cfm, 0.3 Torr
<22 min-1, 0.4 bar
0.6 cfm, 6 psi
Noise level82 db(A)
Inlet ConnectionISO 100
Outlet ConnectionISO 63
Weight1,804 lb1,650 lb
Gear box oil capacity
Minimum
Maximum
1.4 l / 0.37 gal
1.6 l / 0.42 gal
Electrical supply230/460 V

Digital Manuals

What you need, when you need it!